Deos Rattler 22A
This release provides Rattler_Program with trace32-extension.
This page was constructed following the Create Release Wiki instructions.
Description
The previous distribution is at:
\\nx3000\ship\dds\windows\approved\DDS-rattler-deos-jupiter-20211215
The candidate distribution is at:
\\ddsbuild.ddci.com\DDCI_integration\DDS-rattler-deos-jupiter-20220125 ftp://redhat5.ddci.com//Workstation/cygwin-20180401-ddci-dist-jupiter/x86_64/archive/1643150363
Note: The candidate distribution was created as a new DDS using all latest stable components via the DDS Build Process.
Components to Work
Below are the Deos components that have been identified to work for this release. See also the list of Recent FTP server unreleased symbolic links.
Component Constraints: Refresh constraints
- Must be installed together:
- ansi-4.12.0
- desk-headers-1.0.0
- desk-headers provides stdio.h which includes stdio-ansi.h which is provided by ansi-4.12.0.
- Must be installed together:
- vfile-8.0.0
- vfileconfig-1.13.0
- kernel-11.8.0
- ftpserver-11.7.0
- desk-headers-1.0.0
- ansi-4.12.0
- vfileconfig-1.13.0 updates to schema 10 which is required by vfile-8.0.0.
- kernel-11.8.0 updates libkfs.so vfile driver to vfile-8.x.
- ftpserver-11.7.0 updates to vfile-8.x.
- desk-headers-1.0.0 provides stdio.h in lieu of ansi providing it.
- Must be installed together:
- bsp-common-3.4.0
- bsp-common-3.4.0 requires OpenArbor-12.6.0
- bsp-common-3.4.0
- Must be installed together:
- deos-rtems-introspection 1.5.0
- status-monitor 11.6.0
- gdbserver-ddci 11.2.2
- Also recommended: RTEMS 6.0.1 (deos-rtems-docs deos-rtems-adapter-aarch64 deos-rtems-adapter-arm deos-rtems-adapter-common deos-rtems-adapter-ppc deos-rtems-adapter-x86 deos-rtems-adapter-x86-64 deos-rtems-tools-aarch64 deos-rtems-tools-arm deos-rtems-tools-common deos-rtems-tools-ppc deos-rtems-tools-x86 deos-rtems-tools-x86-64 deos-rtems-autotools)
See also BDU_Script_Maintenance.
| Components | Version | Phase | CCB | Who | Test Report | Release Notes |
|---|
Legend
CCB: A Release CCB has been held
Phases:
- Dev - In Development
- Test - Component unreleased and ready to test
- Delta - A Delta baseline must be established
- Audit - One (or more) SQA Audits must be performed (e.g., a Verification and/or Software Conformity Audit)
- Stable - You are done! All steps (including test report) in the Deos Software Release HowTo or OpenArbor Development HowTo have been followed.
Who: The person responsible for doing the work associated with the component.
Remarks: Free form text. It must contain the test report when done.
Differences from Prior Release
Added/Modified Packages
In addition to the components listed in table above, these components are also present
New Packages
- gcc-arm-eabi-7.3.0-4
- trac-arm-279-1
- trac-common-279-2
- trac-docs-279-1
- trace32-extension
Updated Packages
- N/A
Removed Components
- N/A
Unreleased Components
An analysis has been performed, and it was determined that the following components should not be included in this release:
- N/A
DDS Test Summary
No additional OA required. Will leverage off OpenArbor 10.4.0 Test Plan and Report Rattler 21A
| Charge Code | BSP | Target Hardware | Test Suite | Remarks |
|---|---|---|---|---|
| N/A | N/A | N/A | N/A | N/A |
| N/A | N/A | N/A | N/A | N/A |
Trac ARM Version 279 Test Report Trac 80x86 Version 278 Test Report Trac PPC Version 278 Test Report
Additional Testing
diff -rq DDS-rattler-deos-jupiter-20211215 DDS-rattler-deos-jupiter-20220125
Diff Result
Known Problems