OpenArbor 10.4.2 Test Plan and Report Crucible D1

From DDCIDeos
Jump to navigationJump to search


About

OpenArbor Windows 10.4.2
SVN Revision: r99352
SVN Branch Name: 10.4.2

Test Schedule

Scheduled Test Runs Start Date Due Date Delivered Percentage Complete
Formal Run 06/01/2022 06/03/2022 06/03/2022 100%

Introduction

The automated test suites for Eclipse, supports Eclipse 2020-R-12, which OpenArbor is built upon. The tests were run the on build mentioned above.

A list of PCRs corrected for this release can be found here: OpenArbor_10.4.2

See below for a list of machines that will be used to reproduce/fix test failures.

The test logs can be viewed at:

\\nx3000\openarbor\TestResults\Release10.4.2

Legend

Pass The test passed.
Expected Deviation The test fails and a fix is not going to happen due to technical restrictions or restraints beyond our control.
Known Failure The test fails, but we have plans to fix the problem in a future release.
Fail The test failed.
Not scheduled to be tested for this release.
X Scheduled to be tested for this release.
Not Supported.

Test Machines

Machine OS
OATEST Windows 7 (64bit)
OATESTLAP Windows 10 (64bit)
TESTW10E1 Windows 10 (64bit)
TESTW10E2 Windows 10 (64bit)
TESTW7P2 Windows 7 (64bit)

Executed Formal Test Runs

The automated OpenArbor Test Suites are executed for each entry in the table below. The "Test Suites" column will indicate what tests were run. The full set of OpenArbor tests are indicated by the name Launcher. A second test suite, CompileRunDebug is used to just test compilation, linking, running and debugging the example projects. The PlatformIntegration test suite is a small set of tests that exercise the more common operations customers use in interacting with the platform.

Product DDS Release Timestamp Target
Architecture
Available
Boards
Test Suites Test Machine Who Formal
Results
Comments
Deos DDS-crucible-deos-jupiter-20220601 1654108771 arm DeosS32V234-3 (s32v234) PlatformIntegration OATEST NH Pass See Testing Notes

Testing Notes

ID Priority OS PCR Status Affected Tests Target Screenshot Comments
0 Windows n/a n/a DDS modification for testing DeosS32V234-3 (s32v234) Media:lwip_config_s32v234.txt The \desk\platform\s32v234\etc\lwip.config file was replaced in the DDS to allow for communication with the target board.
1 Windows Expected Failure Debug.trasher
Debug.worker
Run.trasher
Run.worker
DeosS32V234-3 (s32v234) Media:TrasherWorkerBuildFailure2.png Platform project fails to build when the Multicore-memory-pools example projects trasher and worker are integrated into the out of the box single core and/or single pool platform. The MulticoreIntegration test performs the BuildAll, Run and Debug tests for the multicore memory pools examples in a multicore/multi memory pool environment.
2 Windows DDCI_PCR:4041 Known Issue DeosOptionTabs.integrationToolTabTest DeosS32V234-3 (s32v234) binder.xml files are not currently being validated in OpenArbor.
3 Windows DDCI_PCR:4345 OA Test Update Run.vfile_logbook_partition1 DeosS32V234-3 (s32v234) Extra steps required to run this example. OA test update needed to automate these steps.
4 Windows DDCI_PCR:4443 OA Test Update Run.dvmssimple-raw
Run.dvmssimple-with-exfat
Run.dvmssimple-with-journaled-exfat
DeosS32V234-3 (s32v234) OA test update needed to create patterns for new examples.
5 Windows Expected Failure compileRunDebug.CffsMal DeosS32V234-3 (s32v234) Mal file: [C:\oaTestHarness\workspace\DDS-list\DDS-crucible-deos-jupiter-20220601\desk\etc\cffss32emmc.cd.xml] does not exist in the DDS desk\etc folder.
6 Windows DDCI_PCR:4052 OA Test Update deos.StatusMonitor DeosS32V234-3 (s32v234) Test update is needed. Pool Low Water Mark value fails to change.
7 Windows Expected Failure Debug.serial-echo
Run.serial-echo
Debug.tx-duart-nxp
Run.tx-duart.nxp
DeosS32V234-3 (s32v234) These examples only work on the nai68ppc2 bsp (per CP).
These examples were removed from non nai68ppc2 test workspaces.
8 Windows Expected Failure MulticoreIntegration DeosS32V234-3 (s32v234) Multicore Integration testing cannot be performed on the s32v234 platform.